The Cerabar PMP51 digital pressure transmitter with metal membrane is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. PMP51 is designed for high pressure applications up to 400bar. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511. |
Accurate measurement of the process value even in the case of changing process temperature
Process safety assured with small flush mounted process connections in hygienic applications
For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
Modular concept for easy replacement of display or electronics
Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
Seamless and independent system integration (HART/PA/FF)
Single chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h
Measuring range: -1/0 up to +400bar (-15/0 up to +6,000psi)
Accuracy: ±0.15%, "Platinum" ±0.075%
International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals
Features and specifications |
Continus Liquids Level |
|||||||||||||||||||||||||||||||||||||||||||||||||
|
Pressure measurement |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Product pictures: |
|
|
What's the difference between PMC51,PMP51 and PMP55? |
Cerabar M – Product family |
PMC51 |
PMP51 |
PMP55 |
With capacitive measuring cell and ceramic process isolating diaphragm(Ceraphire®) |
With piezoresistive measuring cell and metallic welded process isolating diaphragm |
With diaphragm seal | |
Field of application | – Gauge pressure and absolute pressure – Level |
||
Process connections | – Thread – EN flanges DN 25 – DN 80 – ANSI flanges 1" – 4" – JIS flanges 50 A – 100 A – Flush-mounted hygienic connections |
– Thread – EN flanges DN 25 – DN 80 – ANSI flanges 1" – 4" – Prepared for diaphragm seal mount – Flush-mounted hygienic connections |
– Wide range of diaphragm seals |
Measuring ranges | From –100/0 to 100 mbar (–1.5/0 to 1.5 psi) to –1/0 to 40 bar (–15/0 to 600 psi) |
From –400/0 to 400 mbar (–6/0 to 6 psi) to –1/0 to 400 bar (–15/0 to 6000 psi) |
|
OPL 1) | Max. 60 bar (900 psi) | Max. 600 bar (9000 psi) | |
Process temperature range | –40 to +130 °C (–40 to +266°F) For a maximum of 60 minutes: +150 °C (+302 °F) |
–40 to +130°C (–40 to +266°F) For a maximum of 60 minutes: +150 °C (+302 °F) |
–70 to 400 °C (–94 to +752 °F) depending on the filling oil |
Ambient temperature range | – Without LCD display: -40 to +85°C (–40 to +185 °F) – With LCD display: –20 to +70°C (–4 to +158°F) (extended temperature application range (-40 to 85°C (-40 to 185°F)) with restrictions in optical properties such as display speed and contrast) – Separate housing: –20 to +60°C (–4 to +140°F) – Diaphragm seal systems depending on the version |
||
Reference accuracy | – Up to ±0.15% of the set span – PLATINUM version: up to ±0.075% of the set span |
Up to ±0.15% of the set span | |
Supply voltage | – 11.5 to 45 V DC (versions with plug-in connection 35 V DC) – For intrinsically safe device versions: 11.5 to 30 V DC |
||
Output | 4 to 20 mA, 4 to 20 mA with superimposed HART protocol | ||
Options | – PMP51, PMP55: NACE-compliant materials – PMC51, PMP51, PMP55: inspection certificate 2.2 or 3.1 or other certificates – 3A approval and EHEDG approval – Specific firmware versions – Initial device settings – Separate housing – Broad range of accessories |
||
Specialties | – Metal-free measurement with PVDF connection – Special cleaning of the transmitter to remove paint-wetting substances, for use in paint shops |
– Process connections with minimum oil volume – Gas-tight, elastomer-free |
– Wide range of diaphragm seals – For extreme medium temperatures – Process connections with minimum oil volume – Completely welded versions |
Single carton package |
Package for special products(following is radiative resource) |
Transfer with tray |
Shipping with wooden case |
|
|
Shipment | |
|
Authorised by Endress+Hauser | |
company receptionist |
Office |
Workshop/workers are testing boards |
Worshop equipment |
Our warehouse |
|
Warranty: |
|
Contact us: |
Shenzhen Yearstar Intelligent Technology Co., Ltd. Address:East 4th Floor, NO.1 Bldg,Pingshan Minqi Technology Park, Xili, Nanshan District, Shenzhen, China Tel: + 86 755 2608 6930 ext. 864 Mobile Phone: +86 13244706006 QQ:120554877 Skype:sophie wang |
Why choose us? |
|
1What kind of payment could I choose? |
For the moment,T/T,Western Union,MoneyGram,Paypal are available.
|
2.What's the deliver time?(for E+H products only) |
If the product is in stock,shipment can be delivered within 2 days after receiving payment.If it's out of stock,.after receiving payment,we'll inform to produce, deliver date depends on producing place,6-8 weeks if it's produced in Suzhou,China ; 8-10 weeks if it's produced aboard.
|
3.Express,by sea or by air,what should I choose? |
If the gross weight is less than 45KGs, we suggest express,DHL,Fedex,UPS,TNT,EMS express are available;
|
4.Due to E+H products should be selected according to different environment condition, how can I get exact type? |
Tell us necessary environment parameters(temperature,tube diameter,pressure,density,flow speed...),we can choose for you;Or you can choose by yourself, we can provide type-choosing materials for you. |